Thru-the-wall
Air Conditioners and Heat Pumps
115-Volt: WS08, WS10, WS14
230-Volt: WS10, WS13, WS16, WE10, WE13, WE16, WY10, WY13
M
72
Power
Cool
FSaanver®
Money
Mode
Speed
Fan Only
Clock
Set
Tim
Hour
Start Time
On/Off
Stop Time
Temp/Hour
920-007-13 (8-07)
920-007-13
WELCOME to years of economical comfort
Your new Friedrich Room Air Conditioner has been carefully
engineered and manufactured to give you many years of dependable,
efficient operation, keeping your room at a comfortable temperature
and humidity level. Many extra features have been built into your
Friedrich Room Air Conditioner to assure quiet operation, greatest
circulation of cool, dry air, most flexible selection of function controls,
and high economy of operation.
6. Have a fireplace? Be sure the damper is closed during air
conditioner operation.
7. When it’s time to reroof or repaint the outside of your home,
choose light colors. They reflect heat instead of absorbing it.
8. Shade your outside walls (especially on the west) from the direct
sun; most importantly, shade the unit itself Trees and shrubs
provide natural shading, but make sure they don’t block the air
flow around the unit. If natural shade isn’t present, awnings are
the best solution for shading the unit and the windows. Also,
avoid areas where too much dust or pollen would be drawn
into the air conditioner.
There are many things you can do in and around your home to save
more money - and even increase the efficiency and long life of your
Friedrich unit. Here are a few examples:
1. How to Set Thermostat: When you first turn on your air
conditioner, select the highest fan speed and set the thermostat
to its coldest position to cool the room. When the desired
temperature is reached, turn the thermostat control toward
"warmer" until the compressor goes off. The thermostat
will then cause the compressor to go on and off to maintain
this selected temperature. You can adjust the fan speed for
optimum air circulation.
9. Inside the house, use blinds, screens, or drapes on windows
exposed to the sun. They will reduce your cooling needs.
(Lined or insulated draperies will also help cut heating costs
in winter).
10. Make sure your attic area is properly vented. In addition,
consider installing turbine or power ventilators to help remove
hot air from your attic.
2. Do not block the flow of air to and from the unit - make sure the
louvers are directed to give even distribution of air throughout
the room. Caution: If air is obstructed and/or deflected back
into the air conditioner, this may cause the unit to cycle on and
off rapidly, which could damage your unit.
11. Keep your Friedrich unit clean. Use a vacuum cleaner
attachment for accessible parts, but take care not to damage
them. Clean the reusable filter at least twice a month.
12. Set the thermostat at a higher temperature - save 5% in energy
usage for each degree of temperature over 72°F.
3. Adequate insulation - walls, ceilings, and below floors - can save
up to 50% of the cost of cooling in most areas of the country.
These are the most important suggestions for saving money on
cooling costs. Some, however, may not be applicable to your house
or area. Check with your local utility company for more specialized
information.
4. Caulking: in well insulated homes, air leaks around doors,
windows, lighting and plumbing fixtures can account for as
much as 30% of the load on heating and cooling systems. See
that all these areas are well caulked.
5. Install weather stripping (metal is preferable to felt) around
exterior doors and windows.
Electrical Data
Circuit Rating, Breaker
or Time Delay Fuse
Model
Plug Type
WS08, WS10, WS14
WS10, WS13, WS16
NEMA No. 5-15P
NEMA No. 6-15P
NEMA No. 6-20P
125V-15 AMP
250V-15 AMP
250V-20 AMP
WE10, WE13, WE16,
WY10, WY13
3
920-007-13
How to operate your Friedrich room air conditioner
To start unit
To activate Smart Fan (WY/WE heat-cool models)
If your air conditioner is installed and plugged into a proper receptacle,
it is ready to go. The first time the unit is started, the compressor will
delay for three minutes. See Automatic Component Protection on the
following page.
9
Press the Smart Fan button to activate the Smart Fan. The light
will indicate that this feature is in use.
Smart Fan will adjust the fan speed automatically to maintain the
desired comfort level. For example, if the outside doors in your home
are opened for an extended period of time, or more people enter a
room, Smart Fan may adjust to a higher fan speed to compensate
for the increased heat load. This keeps you from having to adjust
the fan speed on your own.
1
Touch the Power button once. The unit will automatically be in
Cool mode with the temperature set at 75 F (24 C) and the fan
°
°
speed at F1, the sleep setting.
To set mode of operation
When you first turn the unit on, it will be in the Cool mode with con-
To set the hour clock
stant fan.
10
Touch the Set Hour button to see the current setting. The
number that is displayed is the approximate time (hour only).
2
On WS cool-only models, touch the Mode buton once to activate
theMoneySaver® (WS models only. See item 14 for Money Saver
instructions on WY/WE models).
MoneySaver® is a feature that cycles the fan with the com-
pressor so that the fan does not run all the time. This saves
energy and improves dehumidification. MoneySaver® will also
run to test the temperature if the off cycle is too long. Or you
may prefer constant fan for more air movement. (To return to
constant fan, touch the Mode button two more times).
Use the and
buttons to change the settings. BE SURE
TO SET A.M. AND P.M. ACCORDINGLY. (P.M. is indicated by
a red light in the upper left corner of the display).
To set the timer
NOTE: Set the HOUR CLOCK (Set Hour) before attempting to set
timer functions.
You can set the Start Time and Stop Time a minimum of one hour
apart, and a maximum of 23 hours apart.
In order to run the fan by itself, do the following:
On WY/WS heat-cool models, touch the Mode button once to
activate the Fan Only feature. The Fan Only setting will circulate
air in the room without the compressor coming on.
11
After setting the time, press the Set Hour button once (Start
light on). Use the and buttons to select the time that the
unit will START.
Continuing from MoneySaver® mode, touch the Mode button
once to activate the Fan Only feature (WS cool-only models.
3
12
After selecting the Start Time, press the Set Hour button once.
(Stop Light on). Use the
and
buttons to select the time
that the unit will STOP. After selecting the stopping time, press
the Set Hour button once.
To adjust temperature
Use the Mode button to select either the Cool or MoneySaver®
function (or Heat for WY/WE heat-cool models)
4
13
Press the Timer On/Off button (light turns on) to activate the
timer function. To deactivate this function, press the Timer
On/Off button once again (light turns off). Once the on and
off times have been selected, they will remain in memory and
cycle daily until changed.
5
6
7
COOLER – Touch the button to lower the room air temperature.
WARMER–Touchthe buttontoraisetheroomairtemperature.
NOTE: If the unit is unplugged or the power is interrupted, the HOUR
must be reset or the Timer On/Off will not function when desired.
Press both the
and
buttons at the same time to switch
the temperature from Fahrenheit (°F) to Celsius (°C). Repeat
Step 7 to switch from °C back to °F.
To Activate Money Saver (WY/WE models)
To adjust fan speed
14
Press the Money Saver button to activate the Money Saver
8
Touch the Fan Speed button to see the current setting. Touch
it again to change speed. F1 is the lowest setting (SLEEP
SETTING / LOW), F2 is MEDIUM, and F3 is HIGH.
feature. The light will indicate the Money Saver is in use.
MoneySaver® is a feature that cycles the fan with the com-
pressor so that the fan does not run all the time. This saves
energy and improves dehumidification. MoneySaver® will also
run to test the temperature if the off cycle is too long. Or you
may prefer constant fan for more air movement. (To return to
constant fan, touch the Mode button two more times).
To activate Smart Fan (WS cool-only models)
9
There is a fourth option, SF, when selecting the fan speed. This is
the SMART FAN function. SMART FAN DOES NOT OPERATE
IN CONJUNCTION WITH THE FAN ONLY MODE.
4
920-007-13
PM
1
Power
72
72
2
8
9
3
4
1
Power
Cool
2
8
3
9
4
Cool
Fan
Smar
Fan
Fan Only
Heat
6
5
Fan
MoneySaver®
Mode
Speed
Speed
Mode
6
5
Fan Only
7
7
Clock
Clock
Money
Saver
Timer
Set
Start Time
Stop Time
Timer
Set
Start Time
Stop Time
14
13
On/Of
Hour
13
On/Off
Hour
Temp/Hour
Temp/Hour
10 11 12
10 11 12
Figure 1: WS Model cool-only control panel
Figure 2: WY/WE Model heat-cool control panel
Automatic component protection
Your unit is equipped with Automatic Component Protection.
To protect the compressor of the unit, there is a three minute delay
if you turn the unit off or if power is interrupted. The fan will not be
affected. Also, if you switch from Cool mode to Fan Only mode, and
switch back to Cool mode, there is a three-minute delay before the
compressor comes back on.
Using the remote control
To adjust temperature
To start unit
6
1
WARMER - Press the Warmer button to raise the temperature setting.
POWER - Press the Power button once. The unit will automatically
start in the mode and fan speed it was last left on.
7
COOLER - Press the Cooler button to lower the temperature setting.
To set mode of operation
To adjust fan speed
2
COOL - Press the Cool button to automatically switch the operat-
8
FAN SPEED - Press the Fan Speed button to see the current
setting. Press again to change the fan speed. F1 is the lowest
setting (SLEEP / LOW), F2 is MEDIUM, F3 is HIGH, and SF is
the SMART FAN setting.
ing mode to COOL.
3
4
FAN ONLY - Press the Fan Only button if you want to run the
fan only.
HEAT (WY/WE models only) - Press the Heat button to
To set the hour clock
automatically switch the operating mode to HEAT.
9
SET HOUR CLOCK - Press the Set Hr. button once to see the
current clock setting. Continue pressing the button until you
arrive at the current time (Hour only). Minutes are not shown on
the display. Make sure that the A.M. / P.M. setting is correct.
MoneySaver® - Press the Money Saver® button to activate
the MoneySaver® feature. This feature cycles the fan with the
compressor so that the fan does not run all the time.
5
5
920-007-13
To set the timer
NOTE: You can set the START and STOP times a minimum of one
hour apart, and a maximum of 23 hours apart.
10
11
12
TIMER START - Press Start to view the current start time for cool-
ing. Continue pressing the START button until you arrive at the start
time you desire. The start time for cooling will then be set.
Temperature
Cooler
Warmer
Heat
7
6
1
Power
Cool
TIMER STOP - Press the Stop button. Continue pressing the
STOP button until you arrive at the stop time you desire. The
stop time for cooling will then be set.
2
3
4
5
8
9
Fan
Fan
Money
Saver®
Only
Speed
Timer Operation
On/Off Start Stop Set Hr.
TIMER ON / OFF - Press the On/Off button (under Timer
Operation) to activate (light on) or deactivate (light off) the timer.
Once the on and off times have been selected, they will remain
in memory and cycle daily until changed.
12
10
11
NOTE: If the unit is unplugged or the power is interrupted, the Set Hr.
function must be reset or the Timer On/Off function will not work.
Figure 3: WY/WE heat-cool model remote control
Additional RC1 wireless remote controls can be purchased from your Friedrich dealer.
How to clean the air filter
Your Friedrich room air conditioner is equipped with a Permafoam
reusable air filter which is not affected by washing. The filter serves to
remove dust, pollen, and other impurities from the air.
P
72
Speed
Mode
C
On
oo
l
/O
Po
w
ff
Hour
M
on
ey
er
Fa
n
SavFa
er
On
®
n
Filter
ly
C
lo
ck
S
Set
t
tar
Ti
S
m
e
to
p
Ti
m
e
T
e
m
p/Hour
KEEP THE FILTER CLEAN - A clogged, dirty filter will reduce the
operating efficiency of your unit and contribute to frosting of the
indoor coil. Be sure to check the filter every 7 to 10 days. The filter
check procedure is easy, due to the unique design of the Friedrich
DECORATIVE FRONT.
FILTER ACCESS - Remove the INTAKE GRILLE from the
DECORATIVE FRONT frame by grasping it at the upper right and
left side corners. Pull out until the GRILLE is released from the upper
retaining snaps. Tilt down toward you, lift up and out of the bottom
retaining snaps. This will expose the filter. Remove the filter by pulling
it toward you. Wash the filter in hot, soapy water, rinse, squeeze lightly
to remove excess water, shake dry - do not twist - and replace in the
unit on the two support hangers. Replace the INTAKE GRILLE by
positioning the bottom of the GRILLE into the bottom retaining snaps.
Tilt the front up and away from you. Press in lightly on top and the
GRILLE will position itself into the upper retaining snaps.
Intake Grille
Figure 4
6
920-007-13
How to change airflow direction
Electrical requirements
The DISCHARGE GRILLE is installed at the factory to provide 45˚
upward airflow into the room. (Direction 1 in Figure 5). If a vertical
airflow is desired (Direction 2), the direction can be changed by rotating
the DISCHARGE GRILLE.
IMPORTANT: Before you begin the actual installation of your air
conditioner, check local electrical codes and the information below.
Your air conditioner must be connected to a power supply with the same
AC voltage and hertz rating as marked on the nameplate located on
the chassis. Only alternating current (AC) can be used. Consult pages
3 and 7 for the correct type of receptacle for your model.
Unplug the air conditioner.
Remove the DISCHARGE GRILLE RETAINER attached with one
screw in the right side of the grille.
An overloaded circuit will invariably cause malfunction or failure of an
air conditioner, therefore, it is extremely important that the electrical
power and the wiring is adequate. Consult your dealer or power
company if in doubt.
Remove the DISCHARGE GRILLE from the retaining slots near the
CONTROLS, and rotate the grille as shown in Figure 5.
Reinstall the DISCHARGE GRILLE by placing it in its retaining slots.
Reattach the DISCHARGE GRILLE RETAINER with the retaining
screw. The unit is now ready to operate.
CIRCUIT PROTECTION - Before installing or relocating your
Friedrich Room Air Conditioner, check the amp rating of the circuit
breaker or "TIME-DELAY" fuse. Refer to the nameplate located on
the air conditioner chassis to determine the correct fuse or circuit
breaker amperage for your model. The rating MUST NOT exceed
the value stated on the nameplate. If the air conditioner is connected
to a circuit protected by a fuse, a "TIME-DELAY" fuse must be
used due to the momentary high current demands when your air
conditioner is started.
How to cover inner weather panel holes
Two beige plugs are included in the plastic bag taped to the WallMaster
chassis. These plugs may be used to cover the two holes left after
removing the inner weather panel (see Figure 5). The plugs must be
attached before the DECORATIVE FRONT frame is installed.
Figure 5
1" Diameter Plug
WSC
Sleeve
2
Rotate
2
2
Airflow
Decorative
Front
5
1
A
3
6
W
7
B
1
M
E
1
Discharge
Grille
Return
Air Grille
7
920-007-13
Never use an extension cord
Once plugged in the unit will operate normally without the need to
reset the LCDI device.
Your Friedrich room air conditioner is equipped with a three-prong
(grounded) plug for your protection against shock hazards and should
be plugged directly into a properly grounded three-prong receptacle.
If you have a two-prong receptacle you will need to have the circuit
replaced by a certified electrician with a grounded circuit that meets
all national and local codes and ordinances. Under no circumstances
should you remove the ground prong from the plug. You must use the
three-prong plug furnished with the air conditioner.
If the device fails to trip when tested or if the power supply cord
is damaged it must be replaced with a new supply cord from the
manufacturer. We recommend you contact our Technical Assistance
Line at (800) 541-6645 ext. 662. To expedite service, please have your
model and serial number available.
NEVER CUT OR REMOVE THE GROUNDING PRONG FROM THE
PLUG.
NOTE: Your LCDI device will resemble one of these illustrations.
Power cord information
All Friedrich room air conditioners are shipped from the factory with
a Leakage Current Detection Interrupter (LCDI) equipped power
cord. The LCDI device meets the UL and NEC requirements for cord
connected air conditioners effective August 2004.
RESET
TEST
RESET
WARNING
TEST BEFORE EACH USE
1. PRESS RESET BUTTON
TEST
To test your power supply cord:
2. PLUG LDCI INTO POWER
RECEPTACLE
3. PRESS TEST BUTTON,
RESET BUTTON SHOULD
POP UP
1. Plug power supply cord into a grounded 3 prong outlet.
4. PRESS TEST BUTTON,
FOR USE
DO NOT USE IF ABOVE TEST
FAILS
2. Press RESET (See Figure 6).
WHEN GREEN LIGHT IS ON
IT IS WORKING PROPERLY
3. Press TEST (listen for click; Reset button trips and pops
out).
4. Press and release RESET (listen for click; Reset button
latches and remains in). The power supply cord is ready for
operation.
NOTE: LCDI device is not intended to be used as a switch.
Figure 6
8
920-007-13
Troubleshooting tips and home maintenance
Won’t cool
Frosting of the indoor coil
If the unit operates, but won’t cool, determine if the controls are
properly set. Wait three minutes before setting the thermostat to a
cooler position in order to check control settings. Check the filter and
clean it thoroughly, if needed. Check to see if the vent door is closed.
Check to see if the chassis seal gasket is properly installed (refer to
page 14 for seal gasket installation).
Certain operating conditions may produce indoor coil frost. During
the cooling operation, a dirty filter or restricted air distribution in
combination with cool, damp weather could cause such an occurrence.
Should the indoor coil frost over while cooling, set the control to FAN
and keep it running until the frost on the coil is gone. Setting the
thermostat to a slightly warmer position will probably keep the coil
from frosting over again.
Won’t heat (for heat/cool models only)
If the unit operates, but won’t heat, determine if the control settings are
correct. Adjust the thermostat to a warmer position to determine if it
operates. Also, check the filter and clean it thoroughly, if needed.
Cleaning the decorative front
The decorative front of your Friedrich room air conditioner, as well
as the complete cabinet, may be cleaned with warm water and mild
detergent. Under adverse operating conditions, the indoor and outdoor
coils and base pan may require periodic cleaning to maintain efficient
operation. Your Friedrich dealer should be called when this service
is required.
Odors in heating (for heat/cool models only)
You may notice a smoke odor the first time the heater element comes
on. This is common in any type of heat system when first turned on
for the winter. The odor comes from dust and other particles that
accumulate during the warm months. The odor will dissipate quickly.
Won’t run
If the unit fails to operate, check to see if the power cord is firmly
plugged in. Check for blown fuses, tripped circuit breakers or a
tripped LCDI Device (Refer to LCDI reset instructions in the Power
cord information section). Restore the circuit breaker or replace the
blown fuse with a proper size "TIME-DELAY" fuse. The proper fuse
size is shown on pages 4 and 7 in these instructions. After restoring
the current supply to the unit, wait three minutes before restarting.
Things to know about a WallMaster heat pump
During the heat pump operation, you may notice some functions that did not occur when the unit was used for cooling:
1. It is common for ice to form on the outdoor coil of your WallMaster Heat Pump. The ice forms due to moisture in the outdoor
air passing over cold (below freezing) coil surfaces.
2. When the outdoor coil forms ice, your heat pump will automatically initiate a defrost. The compressor will stop and the fan will
continue to run. The electric heat will be turned on to continue warming the room while the outdoor air defrosts the outdoor
coil. After the defrost is completed, the unit will automatically return to the heat pump mode.
3. It is normal for vapor (steam) to rise from the outdoor coil during the defrost. This is similar to expelling warm breath on a
cold morning.
4. If the outdoor temperature drops below 43°F during heat pump operation, your WallMaster Heat Pump will automatically
switch to electric resistance heat and will continue to operate in this mode as long as the outdoor temperature remains at
43°F or below.
9
920-007-13
Installation instructions for WSC sleeve
Mounting hardware provided
ITEM NO.
DESCRIPTION
QTY.
1
SCREW, #12A x 2"
5
Wall preparation
A. Adjustable SUBBASE (SB) or other unit support must be provided
for panel wall type construction and for walls less than 8" thick.
STEP 1 The wall opening required for a WSC SLEEVE is 17 ¼"
high by 27 ¼" wide.
B. A minimum distance of 1" must be allowed on all sides of the unit
to adjacent wall and floor. Where the subbase is required, the
minimum distance from the floor to the sleeve must be 3 ½". To
minimize chances of short cycling of the compressor, the minimum
clearance between the ceiling and the top of the unit should be
24". (See Figure 8).
STEP 2 LINTELS must be used in opening of brick veneer and
masonry walls to support the material above the WSC
SLEEVE. The following considerations should also be given:
Figure 7
Minimum Of 24" Required
From Top Of Unit To Ceiling.
Inside Wall
Lintels
Minimum Of 1" Spacing
Required On All Sides
Of The Unit.
WSC Sleeve
Drain
Extension
9⁄ " Minimum
16
Beyond Outside
Wall
1" Minimum
3 ½" For Subbase
Outside Wall
10
920-007-13
Installation requirements
STEP 1 The WSC SLEEVE should be positioned so that the
STEP 4 The WSC SLEEVE must also be installed with a downward
9
DRAIN EXTENSION extends a minimum of ⁄ " beyond
16
tilt toward the outside of the building. If a level is placed
so that it rests on the FRONT and BACK UNIT REST as
shown in Figure 8, a properly installed unit provides a ½
bubble slope to the outside of the building.
the OUTSIDE WALL (See Figure 7).
STEP 2 The WSC SLEEVE must extend a minimum of ⅞" beyond
the INSIDE WALL.
CAUTION: SLEEVE projections and leveling precautions
must be observed to prevent the entry of water into the room.
STEP 3 The WSC SLEEVE must be installed level side to side.
Figure 8
Raised Ledge
Back Unit Rest
Level
Front Unit Rest
Sleeve installation
STEP 1 After unpacking the WSC SLEEVE from the carton, remove
the corrugated FRONT PANEL. Place the WSC SLEEVE
in the wall opening following the instructions given in the
INSTALLATION REQUIREMENTS. Attach the SLEEVE to
the INSIDE WALL by driving two #12A x 2" screws in each
side of the SLEEVE (see Figure 7). Shim at the top of the
SLEEVE, midway between the sides. Drive one #12A x 2"
screw in the top of the sleeve, close to the shim. Install
screws from inside the SLEEVE. If the wall opening is not
framed with wood, use expansion anchor bolts or molly
(toggle) bolts (not provided).
STEP 2 Once the SLEEVE has been installed, check the LEVEL
again to be sure the ½ bubble downward tilt is maintained.
Apply shims, if required, to maintain the proper slope.
STEP 3 Caulk the perimeter of the entire opening on the inside and
the outside between the SLEEVE and the WALL.
STEP 4 The corrugated front panel removed in Step 1 above must
be remounted back in place if masonry work is to be done
and/or if the "WallMaster" CHASSIS is to be installed at a
later date.
11
920-007-13
WallMaster chassis installation instructions for WS, WE and WY models
(WSC-A sleeve)
These instructions are provided for installation of WallMaster air
conditioner chassis models into thru-the-wall sleeves. This chassis
has been UL approved with the sleeve listed on the serial nameplate
of this chassis. Important warranty information is provided on pages
17 and 18. Keep these instructions in a convenient location for any
warranty service that may be required.
STEP 2 Check the electrical receptacle to see that it conforms to
the requirements for the chassis model to be installed.
See pages 2 and 5, for the receptacle requirements.
STEP 3 The decorative front is packaged in a separate box inside
the chassis shipping carton, between the chassis and
the carton. Remove this box and set the box aside until
later.
STEP 1 Check the sleeve to be certain it has been correctly installed
in the wall. Remove the corrugated front panel on the WSC
SLEEVE. Remove the rear WEATHER PANEL. Reverse
grille. Place lower edge into sleeve tab (Friedrich logo facing
out). Align slots with screw holes. Secure grille with screws.
STEP 4
With the help of an assistant, remove the chassis from
the shipping carton. Be careful not to allow anything to
impact against the hairpins as this may result in damage
to them. With the help of an assistant, lift the chassis by
the basepan and slide it into the sleeve until it contacts
the rear grille. With the chassis in proper position, the
front edge of the basepan must extend out 4 ¾ inches
from the front (side) edge of sleeve.
A. Check the anchor screws. There should be four
(4) in the WSC SLEEVE (two in each side).
B. Determine if the sleeve has a downward slope,
to the outside, of ½ bubble on a level. See
page 10 for further details.
C. Check to be sure the sleeve has been sealed
around all edges with an industrial type
caulking on both the outside and inside to
prevent rain entry.
Figure 9
Condenser
Shroud
A
1
4
6
3
6
M
12
920-007-13
WallMaster chassis installation instructions for WS, WE and WY models
(WSC-B sleeve)
These instructions are provided for installation of WallMaster air
conditioner chassis models into thru-the-wall sleeves. This chassis
has been UL approved with the sleeve listed on the serial nameplate
of this chassis. Important warranty information is provided on pages
17 and 18. Keep these instructions in a convenient location for any
warranty service that may be required.
STEP 2 Check the electrical receptacle to see that it conforms to
the requirements for the chassis model to be installed.
See pages 2 and 5, for the receptacle requirements.
STEP 3 The decorative front is packaged in a separate box inside
the chassis shipping carton, between the chassis and
the carton. Remove this box and set the box aside until
later.
STEP 1 Check the sleeve to be certain it has been correctly installed
in the wall. Remove the corrugated front panel on the WSC
SLEEVE. Remove the rear WEATHER PANEL. Place lower
edge into sleeve tab (Friedrich logo facing out). Align slots
with screw holes. Secure grille with screws.
STEP 4
With the help of an assistant, remove the chassis from
the shipping carton. Be careful not to allow anything to
impact against the hairpins as this may result in damage
to them. With the help of an assistant, lift the chassis by
the basepan and slide it into the sleeve until it contacts
the rear grille. With the chassis in proper position, the
front edge of the basepan must extend out 4 ¾ inches
from the front (side) edge of sleeve.
A. Check the anchor screws. There should be four
(4) in the WSC SLEEVE (two in each side).
B. Determine if the sleeve has a downward slope,
to the outside, of ½ bubble on a level. See
page 10 for further details.
C. Check to be sure the sleeve has been sealed
around all edges with an industrial type
caulking on both the outside and inside to
prevent rain entry.
Figure 10
Rear weather panel
13
920-007-13
STEP 5 CHASSIS SEAL GASKET INSTALLATION: After
STEP 6 Remove the intake grille from the decorative front frame by
grasping it at the upper right and left side corners. Pull out
until the grille is released from the upper retaining snaps.
Tilt it down toward you, lift up and out of the bottom retaining
snaps. Install the decorative front frame in place over the
sleeve opening and attach it to the chassis with four sheet
metal screws as shown in Figure 11. Replace the intake
grille by positioning the bottom of the grille into the bottom
retaining snaps. Tilt the front up and away from you. Press
in lightly on top, and the grille will position itself into upper
retaining snaps.
installing the shell, slide the chassis into the shell stopping
approximately 3" from full insertion. Stuff the chassis seal
gasket one inch deep between the chassis and the shell
(see Figure 11). Make sure the gasket is installed beginning
from the lower right side corner and extending over the
top and down to the lower left side corner. Then push the
chassis all the way into the shell for the remaining distance
so that the plastic front meets the front edge of the shell.
If chassis seal gasket is not installed, the operation of the
unit will be negatively affected. Also, the operation noise
and outside noise will be amplified.
Figure 11
Chassis Seal
Gasket
Decorative Front
A
2
5
3
7
M
E
W
A
Screws (4)
Return Air
Grille
Attach the frame to the chassis by installing four (4) 8A-5/8" screws through the slots in the frame and into the holes in the chassis.
14
920-007-13
Condensate removal (WS, WE and WY models)
If you desire to drain condensate from the basepan during unit
operation, this unit is provided with a drain nipple that can be
attached to the basepan. You must provide a 3/8" outside diameter
thin-wall plastic or copper tube which will attach to the drain nipple.
Follow the instructions below:
STEP 2
Remove the knockout in the lower right side of the rear
grille. Slide the chassis into the WSC SLEEVE so that
the drain nipple extends through the knockout.
STEP 3
Slide the tubing inside the drain nipple.
STEP 1
Find the drain plate on the rear of the basepan and
remove it. (See Figure 12).
If the chassis must be removed from the sleeve for service, remove
the clamped drain hose before sliding the chassis out of the sleeve.
Figure 12
Drain nipple
Basepan
Drain hose
Sleeve
Alternate drain kits
DK (Drain Kit)
IDK (Interior Drain Kit)
New construction allowing for condensate drain systems built within
the walls can use the Friedrich Interior Drain Kit (Accessory #IDK)
designed for installation in the bottom of the sleeve below the
condensate bellows valve (heat/cool models only).
In the event that the outdoor temperature drops below 37°F, any water
that remains in the chassis basepan is drained into the sleeve pan on
WE and WY models to prevent freezing. (NOTE: In the cooling mode
of the WS, WE and WY models, condensate overflow is possible in
very humid climates). For these particular instances, an optional drain
kit (Accessory #DK) is available for water removal.
15
920-007-13
Friedrich Air Conditioning Company
P.O. Box 1540
San Antonio, TX 78295
210.357.4400
WALLMASTER£
THRU-THE-WALL AIR CONDITIONERS
LIMITED WARRANTY
FIRST YEAR
ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from
date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible
for service. Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service
Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive
remedy within twelve months from the date of the original purchase.
SECOND THROUGH FIFTH YEAR
SEALED REFRIGERANT SYSTEM: If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser
coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in
your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase,
FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will
not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the
Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System. All such cost will be the
sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the
original purchase.
APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District
of Columbia, and Canada. This warranty is not applicable to:
1. Air filters or fuses.
2. Products on which the model and serial numbers have been removed.
3. Products which have defects or damage which results from improper installation, wiring, electrical current
characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication
of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war,
government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.
OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service
Organization in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write
to: Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540.
LIMITATIONS:
THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty
notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY
SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND
EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR
IMPLIED WARRANTY.
NOTE: Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of
consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you.
OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services.
All service calls for explaining the operation of this product will be the sole responsibility of the consumer.
All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to
repairs being made.
(10-04)
16
920-007-13
Friedrich wants you to remain pleased with your Room Air Conditioner. Should further assistance be
needed concerning this warranty, contact:
RAC Warranty, Service and Parts
Friedrich Air Conditioning Co.
P.O. Box 1540
San Antonio, TX 78295-1540
Your personal warranty registration record
WARRANTY REGISTRATION: Please complete and return your Warranty Registration Card (not this
form) immediately and mail to FRIEDRICH.While it is not required that you do so in order to obtain warranty
performance, it registers your warranty, making it easier and faster to verify the period of your warranty cover-
age and to contact you, should field service and/or product recall ever become necessary.
FOR YOUR RECORDS: FILL IN THE FOLLOWING INFORMATION WHEN UNIT IS INSTALLED, SO IT
WILL BE READILY AVAILABLE IF NEEDED LATER.
Model No.
Serial No.
Date Installed
Bought from:
(Dealer name)
(Dealer Address)
(Phone)
(Person to contact)
ALWAYS USE FRIEDRICH FACTORY AUTHORIZED PARTS.
USE OF NON-FRIEDRICH PARTS COULD VOID YOUR WARRANTY
17
920-007-13
18
920-007-13
19
FRIEDRICH AIR CONDITIONING CO.
Post Office Box 1540 • San Antonio, Texas 78295-1540
4200 N. Pan Am Expressway • San Antonio, Texas 78218-5212
210) 357-4400 • FAX (210) 357-4480
Printed in the U.S.A.
920-007-13 (8-07)
|
Campbell Hausfeld IB1000 User Manual
Carrier 19XRV User Manual
Carrier 48SS036 User Manual
Carrier 50PG03 07 User Manual
Danby DESIGNER DAC6300D User Manual
Ford MILAN 2010 User Manual
Friedrich Air Conditioner XQ12 User Manual
Friedrich YL24 User Manual
Fujitsu Automobile Accessories V5505 User Manual
HP Hewlett Packard LaserJet 4345mfp User Manual