FEATURES AND FUNCTIONS  
HORIZONTAL AIRFLOW: COOLING/  
DOWNWARD AIRFLOW: HEATING  
INVERTER  
At the start of operation, a large power is used to bring the  
room quickly to the desired temperature. Afterwards, the  
unit automatically switches to a low power setting for eco-  
nomic and comfortable operation.  
For cooling, use horizontal airflow so the cool air does not  
blow directly on the occupants in the room. For heating,  
use downward airflow to send powerful, warm air to the  
floor and create a comfortable environment.  
COIL DRY OPERATION  
OMNI-DIRECTIONAL AIR FLOW  
(SWING OPERATION)  
The Indoor unit can be dried by pressing the COIL DRY but-  
ton on the Remote Control Unit so as to avoid going moldy  
and restrain the breed of bacterium.  
Three-dimensional control over air direction swing is possi-  
ble through dual use of both an UP/DOWN air direction swing  
and RIGHT/LEFT air direction swing. Since UP/DOWN air  
direction flaps operate automatically according to the oper-  
ating mode of the unit, it is possible to set air direction based  
on the operating mode.  
AUTO CHANGEOVER  
The operation mode (cooling, dry, heating) is switched au-  
tomatically to maintain the set temperature, and the tem-  
perature is kept constant at all times.  
REMOVABLE OPEN PANEL  
The indoor unit’s Open Panel can be removed for easy clean-  
ing and maintenance.  
MINIMUM HEAT OPERATION  
The room temperature can be maintained at 50°F so as to  
prevent the room temperature from falling too far.  
MILDEW-RESISTANT FILTER  
The AIR FILTER has been treated to resist mildew growth,  
thus allowing cleaner use and easier care.  
PROGRAM TIMER  
The program timer allows you to integrate OFF timer and  
ON timer operations in a single sequence. The sequence can  
involve one transition from OFF timer to ON timer, or from  
ON timer to OFF timer, within a twenty-four hour period.  
SUPER QUIET OPERATION  
When the FAN CONTROL button is used to select QUIET,  
the unit begins super-quiet operation; the indoor unit’s air-  
flow is reduced to produce quieter operation.  
SLEEP TIMER  
POLYPHENOL CATECHIN AIR CLEANING FILTER  
When the SLEEP button is pressed during Heating mode,  
the air conditioner’s thermostat setting is gradually lowered  
during the period of operation; during cooling mode, the  
thermostat setting is gradually raised during the period of  
operation. When the set time is reached, the unit automati-  
cally turns off.  
The polyphenol catechin air cleaning filter uses static elec-  
tricity to clean fine particles and dust in the air such as to-  
bacco smoke and plant pollen that are too small to see.  
The filter contains catechin, which is highly effective against  
various bacteria by suppressing the growth of the bacteria  
adsorbed to the filter.  
Note that when the air cleaning filter is installed, the amount  
of air produced decreases, causing a slight decrease in the  
indoor unit’s performance.  
WIRELESS REMOTE CONTROL UNIT  
The Wireless Remote Control Unit allows convenient con-  
trol of air conditioner operation.  
NEGATIVE AIR IONS DEODORIZING FILTER  
It comprises pottery super micro particles which can pro-  
duce negative air ions having the effect of deodorizing and  
can absorb and remit the peculiar smell at home.  
WIRED REMOTE CONTROL UNIT (OPTION)  
The optional wired remote control unit (model No.: UTY-RNBYU) can be used.  
When you use remote control unit, there are following different points as compared with using wireless remote control unit.  
[The additional functions for wired ones]  
• Weekly timer  
Temperature set back timer  
[The restricted functions for wired ones]  
• ECONOMY  
• MAINTENANCE  
And you can use both wired and wireless remote control unit simultaneously.  
(But function is limited)  
[The restricted functions for wireless ones]  
•SLEEP TIMER  
•TIMER  
•MIN. HEAT  
•COIL DRY  
En-2  
Fig. 1  
a15  
a1  
a2  
a9  
a1  
Fig.2  
a10  
a3  
a3  
a16  
a14  
a4  
a5  
a6  
a7  
a12 a13  
a8  
a11  
Fig.3  
a9  
Fig. 5  
a19  
a17  
a18  
Fig.4  
a20  
Fig. 6  
b1  
c1  
c2  
c3  
c6  
c7  
b7  
b2  
b8  
c8  
c9  
b9  
b3  
b4  
b5  
b6  
c4  
c5  
b10  
b11  
c10  
b12  
b13  
b16  
b15  
b14  
Fig. 7  
To facilitate explanation, the accompanying illustra-  
tion has been drawn to show all possible indicators;  
in actual operation, however, the display will only  
show those indicators appropriate to the current op-  
eration.  
En-3  
NAME OF PARTS  
Fig. 1 Indoor Unit  
Fig. 6 Remote Control Unit  
a1 Operating Control Panel (Fig. 2)  
a2 MANUAL AUTO button  
b1 Signal Transmitter  
b2 MODE button  
G When kept on pressing the MANUAL  
AUTO button for more than 10 seconds,  
the forced cooling operation will start.  
G The forced cooling operation is used at the  
time of installation.  
Only for authorized service personnel's  
use.  
G When the forced cooling operation starts  
by any chance, press the START/STOP but-  
ton to stop the operation.  
b3 MIN.HEAT button  
b4 COIL DRY button  
b5 SLEEP button  
b6 TIMER MODE button  
b7 FAN button  
b8 START/STOP button  
b9 SET button (Vertical)  
b10 SET button (Horizontal)  
b11 SWING button  
b12 SET TEMP. button (  
b13 TIMER SET (  
b14 CLOCK ADJUST button  
b15 TEST RUN button  
/
)
a3 Indicator (Fig. 3)  
a4 OPERATION Indicator Lamp (green)  
a5 TIMER Indicator Lamp (orange)  
/
) button  
G If the TIMER indicator lamp flashes when  
the timer is operating, it indicates that a  
fault has occurred with the timer setting  
G
This button is used when installing the air  
conditioner, and should not be used un-  
der normal conditions, as it will cause the  
indoor unit’s thermostat function to oper-  
ate incorrectly.  
(See Page 16 Auto Restart).  
a6 DEFROST Indicator Lamp(yellow)  
a7 COIL DRY Indicator Lamp (yellow)  
a8 Remote Control Signal Receiver  
G
If this button is pressed during normal op-  
eration, the indoor unit will switch to test  
operation mode, and the Indoor Unit’s OP-  
ERATION Indicator Lamp and TIMER Indi-  
cator Lamp will begin to flash simultane-  
ously.  
a9 Open Panel (Fig. 4)  
a10 Front Panel  
a11 Air Filter  
a12 Airflow Direction Louver  
a13 Right-Left Louver  
(behind Airflow Direction Louver)  
a14 Drain Hose  
G
To stop the test operation mode, press the  
START/STOP button to stop the air  
tioner.  
condi-  
b16 RESET button  
c1 Remote Control Unit Display (Fig. 7)  
c2 Temperature SET Display  
c3 Operation Mode Display  
c4 COIL DRY Display  
a15 Air Cleaning Filter  
a16 Power Diffuser  
Fig. 5 Outdoor Unit  
c5 SLEEP Display  
a17 Intake Port  
c6 Transmit Indicator  
a18 Outlet Port  
a19 Pipe Unit  
c7 Fan Speed Display  
c8 SWING Display  
a20 Drain port (bottom)  
c9 Timer Mode Display  
c10 Clock Display  
En-4  
PREPARATION  
CAUTION!  
Load Batteries (AAA/R03/LR03 × 2)  
G Take care to prevent infants from  
accidentally swallowing batteries.  
G When not using the Remote Control Unit  
for an extended period, remove the  
batteries to avoid possible leakage and  
damage to the unit.  
Press and slide the battery compartment lid on the re-  
1
verse side to open it.  
Slide in the direction of the arrow while pressing the  
mark.  
G If leaking battery fluid comes in contact  
with your skin, eyes, or mouth, immedi-  
ately wash with copious amounts of  
water, and consult your physician.  
G Dead batteries should be removed  
immediately and disposed of properly,  
either in a battery collection receptacle  
or to the appropriate authority.  
Insert batteries.  
Be sure to align the battery polarities (  
2
3
) correctly.  
Close the battery compartment lid.  
G Do not attempt to recharge dry batteries.  
Set the Current time  
Never mix new and used batteries, or  
batteries of different types.  
Batteries should last about one year  
under normal use. If the Remote Con-  
trol Unit’s operating range becomes ap-  
preciably reduced, replace the batteries  
and press the RESET button with the tip  
of a ballpoint pen or other small object.  
Press the CLOCK ADJUST button (Fig. 6 b14).  
1
2
Use the tip of a ball-point pen or other small object to press the button.  
Use the TIMER SET (  
/
) buttons (Fig. 6 b13) to  
adjust the clock to the current time.  
button: Press to advance the time.  
button: Press to reverse the time.  
(Each time the buttons are pressed, the time will be advanced/reversed in  
one-minute increments; hold the buttons depressed to change the time  
quickly in ten-minute increments.)  
Press the CLOCK ADJUST button (Fig. 6 b14) again.  
This completes the time setting and starts the clock.  
3
To Use the Remote Control Unit  
G The Remote Control Unit must be pointed at signal receiver (Fig. 3 a8) to operate  
correctly.  
G Operating Range: About 23ft (7 meters).  
G When a signal is properly received by the air conditioner, a beeping sound will  
be heard.  
G If no beep is heard, press the Remote Control Unit button again.  
Remote Control Unit Holder  
Insert  
Slide up  
Pull out  
Press in  
Screws  
1
Mount the Holder.  
2
Set the Remote Control  
Unit.  
3
To remove the Remote  
Control Unit (when use at  
hand).  
En-5  
OPERATION  
To Select Mode Operation  
Press the START/STOP button (Fig.6 b8).  
1
2
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 a4) will light.  
The air conditioner will start operating.  
Press the MODE button (Fig.6 b2) to select the desired  
mode.  
Each time the button is pressed, the mode will change in the following  
order.  
s
s
s
AUTO  
COOL  
DRY  
t
t
HEAT  
FAN  
About three seconds later, the entire display will reappear.  
Example: When set to COOL.  
To Set the Thermostat  
Press the SET TEMP. button (Fig. 6 b12).  
button: Press to raise the thermostat setting.  
button: Press to lower the thermostat setting.  
GThermostat setting range:  
AUTO .................................. 64-88 °F  
Heating ............................... 60-88 °F  
Cooling/Dry ........................ 64-88 °F  
The thermostat cannot be used to set room temperature during the FAN mode (the  
temperature will not appear on the Remote Control Unit’s Display).  
About three seconds later, the entire display will reappear.  
Example: When set to 80°F.  
The thermostat setting should be considered a standard value, and may differ  
somewhat from the actual room temperature.  
To Set the Fan Speed  
Press the FAN button (Fig. 6 b7).  
Each time the button is pressed, the fan speed changes in the following order:  
s
s
s
s
s
AUTO  
HIGH  
MED  
LOW  
QUIET  
About three seconds later, the entire display will reappear.  
When set to AUTO:  
Heating : Fan operates so as to optimally circulate warmed air.  
However, the fan will operate at very low speed when the temperature  
of the air issued from the indoor unit is low.  
Cooling : As the room temperature approaches that of the thermostat setting,  
the fan speed becomes slower.  
Fan  
: The fan runs at the low fan speed.  
Example: When set to AUTO.  
The fan will operate at a very low setting during Monitor operation and at the  
start of the Heating mode.  
SUPER QUIET Operation  
When set to Quiet:  
SUPER QUIET operation begins. The indoor unit’s airflow will be reduced for qui-  
eter operation.  
G SUPER QUIET operation cannot be used during Dry mode. (The same is true  
when dry mode is selected during AUTO mode operation.)  
G During Super Quiet operation, Heating and Cooling performance will be reduced  
somewhat. If the room does not warm up/ cool down when using SUPER QUIET  
Operation, please adjust the air conditioner’s Fan Speed.  
En-6  
OPERATION  
To Stop Operation  
Press the START/STOP button (Fig. 6 b8).  
The OPERATION Indicator Lamp (green) (Fig. 3 a4) will go out.  
About AUTO CHANGEOVER Operation  
AUTO:  
G When AUTO CHANGEOVER operation first selected, the fan will oper-  
ate at very low speed for about one minute, during which time the unit  
detects the room conditions and selects the proper operating mode.  
If the differance between thermostat setting and actual room tempera-  
ture is more than +4 °F Cooling or dry operation  
If the difference between thermostat setting and actual room tempera-  
ture is within 4 °F Monitor operation  
If the difference between thermostat setting and actual room tempera-  
ture is more than –4 °F Heating operation  
G When the air conditioner has adjusted your room’s temperature to near  
the thermostat setting, it will begin monitor operation. In the monitor  
operation mode, the fan will operate at low speed. If the room tem-  
perature subsequently changes, the air conditioner will once again  
select the appropriate operation (Heating, Cooling) to adjust the tem-  
perature to the value set in the thermostat.  
(The monitor operation range is 4 °F relative to the thermostat set-  
ting.)  
G If the mode automatically selected by the unit is not what you wish,  
select one of the mode operation (HEAT, COOL, DRY, FAN).  
About Mode Operation  
Heating: G Use to warm your room.  
G When Heating mode is selected, the air conditioner will operate at very  
During Heating mode:  
Set the thermostat to a temperature set-  
ting that is higher than the current room  
temperature. The Heating mode will not  
operate if the thermostat is set lower than  
the actual room temperature.  
low fan speed for about 3 to 5 minutes, after which it will switch to the  
selected fan setting. This period of time is provided to allow the indoor  
unit to warm up before begin full operation.  
G When the room temperature is very low, frost may form on the outside  
unit, and its performance may be reduced. In order to remove such  
frost, the unit will automatically enter the defrost cycle from time to  
time. During Automatic Defrosting operation, the DEFROST Indicator  
Lamp (yellow)(Fig. 3 a6) will light, and the heat operation will be inter-  
rupted.  
During Cooling/Dry mode:  
Set the thermostat to a temperature set-  
ting that is lower than the current room  
temperature. The Cooling and Dry modes  
will not operate if the thermostat is set  
higher than the actual room temperature  
(in Cooling mode, the fan alone will oper-  
ate).  
G After the start of heating operation, it takes some time before the room  
gets warmer.  
During Fan mode:  
You can not use the unit to heat and cool  
your room.  
Cooling: G Use to cool your room.  
Dry:  
G Use for gently cooling while dehumidifying your room.  
G You cannot heat the room during Dry mode.  
G During Dry mode, the unit will operate at low speed; in order to adjust  
room humidity, the indoor unit’s fan may stop from time to time. Also,  
the fan may operate at very low speed when adjusting room humidity.  
G The fan speed cannot be changed manually when Dry mode has been  
selected.  
Fan:  
G Use to circulate the air throughout your room.  
En-7  
TIMER OPERATION  
Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (P. 5).  
To Use the ON timer or OFF timer  
To Cancel the Timer  
Press the START/STOP button (Fig. 6 b8)  
(if the unit is already operating, proceed to step 2).  
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 a4) will light.  
1
Use the TIMER MODE button to select  
“CANCEL”.  
The air conditioner will return to normal  
operation.  
To Change the Timer Settings  
Press the TIMER MODE button (Fig. 6 b6) to select the  
OFF timer or ON timer operation.  
Each time the button is pressed the timer function changes in the follow-  
ing order:  
2
Perform steps 2 and 3.  
To Stop Air Conditioner Operation  
while the Timer is Operating  
Press the START/STOP button.  
s
s
s
ON  
CANCEL  
OFF  
To Change Operating Conditions  
t
PROGRAM(OFF ON, OFF ON)  
If you wish to change operating conditions  
(Mode, Fan Speed, Thermostat Setting,  
SUPER QUIET mode), after making the  
timer setting wait until the entire display  
reappears, then press the appropriate  
buttons to change the operating condition  
desired.  
The indoor unit’s TIMER Indicator Lamp (orange)(Fig. 3 a5) will light.  
Use the TIMER SET buttons (Fig. 6 b13) to adjust the  
desired OFF time or ON time.  
Set the time while the time display is flashing (the flashing will continue  
for about five seconds).  
3
button: Press to advance the time.  
button: Press to reverse the time.  
About five seconds later, the entire display will reappear.  
To Use the Program timer  
Press the START/STOP button (Fig. 6 b8).  
(if the unit is already operating, proceed to step 2).  
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 a4) will light.  
To Cancel the Timer  
1
Use the TIMER MODE button to select  
“CANCEL”.  
The air conditioner will return to normal  
operation.  
Set the desired times for OFF timer and ON timer.  
To Change the Timer Settings  
2
See the section “To Use the ON timer or OFF timer” to set the desired  
1. Follow the instructions given in the section  
To Use the ON Timer or OFF Timer” to se-  
lect the timer setting you wish to change.  
mode and times.  
About three seconds later, the entire display will reappear.  
The indoor unit’s TIMER Indicator Lamp (orange) (Fig. 3 a5) will light.  
2. Press the TIMER MODE button to select  
either OFF  
ON or OFF  
ON.  
Press the TIMER MODE button (Fig. 6 b6) to select the  
To Stop Air Conditioner Operation  
while the Timer is Operating  
3
PROGRAM timer operation (OFF  
will display).  
ON or OFF  
ON  
Press the START/STOP button.  
The display will alternately show “OFF timer” and “ON timer”, then change  
to show the time setting for the operation to occur first.  
To Change Operating Conditions  
If you wish to change operating conditions  
(Mode, Fan Speed, Thermostat Setting,  
SUPER QUIET mode), after making the timer  
setting wait until the entire display reap-  
pears, then press the appropriate buttons to  
change the operating condition desired.  
G The program timer will begin operation. (If the ON timer has been se-  
lected to operate first, the unit will stop operating at this point.)  
About five seconds later, the entire display will reappear.  
About the Program timer  
G The program timer allows you to integrate OFF timer and ON timer operations in  
a single sequence. The sequence can involve one transition from OFF timer to  
ON timer, or from ON timer to OFF timer, within a twenty-four hour period.  
G The first timer function to operate will be the one set nearest to the current time.  
The order of operation is indicated by the arrow in the Remote Control Unit’s  
Display (OFF ON, or OFF ON).  
G One example of Program timer use might be to have the air conditioner auto-  
matically stop (OFF timer) after you go to sleep, then start (ON timer) automati-  
cally in the morning before you arise.  
En-8  
SLEEP TIMER OPERATION  
Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.  
To Use the SLEEP Timer  
To Cancel the Timer:  
While the air conditioner is operating or stopped, press the  
SLEEP button (Fig. 6 b5).  
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 a4) lights and the TIMER  
Use the TIMER MODE button to select  
“CANCEL”.  
The air conditioner will return to normal  
operation.  
Indicator Lamp (orange) (Fig. 3 a5) light.  
To Stop the Air Conditioner During  
Timer Operation:  
To Change the Timer Settings  
Press the START/STOP button.  
Press the SLEEP button (Fig. 6 b5) once again and set the time  
using the TIMER SET (  
/
) buttons (Fig. 6 b13).  
Set the time while the Timer Mode Display is flashing (the flashing will continue  
about five seconds).  
button: Press to advance the time.  
button: Press to reverse the time.  
About five seconds later, the entire display will reappear.  
About the SLEEP Timer  
To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting  
in accordance with the set time setting. When the set time has elapsed, the air conditioner completely stops.  
During Heating operation:  
During Cooling/Dry operation:  
When the SLEEP timer is set, the thermostat setting is  
automatically lowered 2 °F every thirty minutes. When the  
thermostat has been lowered a total of 8 °F, the thermostat  
setting at that time is maintained until the set time has elapsed,  
at which time the air conditioner automatically turns off.  
When the SLEEP timer is set, the thermostat setting is auto-  
matically raised 2 °F every sixty minutes. When the thermo-  
stat has been raised a total of 4 °F, the thermostat setting at  
that time is maintained until the set time has elapsed, at which  
time the air conditioner automatically turns off.  
SLEEP timer setting  
SLEEP timer setting  
2 °F  
4 °F  
6 °F  
8 °F  
Set time  
30  
minutes  
1 hour  
1 hour  
4 °F  
2 °F  
1 hour  
30 minutes  
Set time  
En-9  
ADJUSTING THE DIRECTION OF AIR CIRCULATION  
G Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Control Unit.  
G Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airflow-direction louvers have  
stopped moving.  
R
Vertical Air Direction Adjustment  
DANGER!  
G Never place fingers or foreign objects in-  
side the outlet ports, since the internal fan  
operates at high speed and could cause  
personal injury.  
Press the SET button (Vertical) (Fig. 6 b9).  
Each time the button is pressed, the air direction range will change as follows:  
1
2
3
4
5
6
7
G Always use the Remote Control Unit’s  
SET button to adjust the vertical airflow  
louvers. Attempting to move them  
manually could result in improper op-  
eration; in this case, stop operation and  
restart. The louvers should begin to  
operate properly again.  
Types of Air flow Direction Setting:  
For better heating/cooling effect, it is recommended to set the air direction in the  
following range.  
1,2,3 :  
4,5,6,7:  
During Cooling/Dry modes  
During Heating mode  
The Remote Control Unit’s display does  
not change.  
G During use of the Cooling and Dry  
modes, do not set the Air Flow Direc-  
tion Louvers in the Heating range (4 -  
7) for long periods of time, since wa-  
ter vapor may condense near the out-  
let louvers and drops of water may drip  
from the air conditioner. During the  
Cooling and Dry modes, if the Air Flow  
Direction Louvers are left in the heat-  
ing range for more than 30 minutes,  
they will automatically return to posi-  
tion 3.  
G Use the air direction adjustments within the ranges shown above.  
G The vertical airflow direction is set automatically as shown, in accordance with  
the type of operation selected.  
During Cooling/Dry mode : Horizontal flow 1  
G When used in a room with infants, chil-  
dren, elderly or sick persons, the air  
direction and room temperature  
should be considered carefully when  
making settings.  
During Heating mode  
: Downward flow 6  
G During AUTO mode operation, for the first minute after beginning operation,  
airflow will be horizontal 1; the air direction cannot be adjusted during this pe-  
riod.  
The air flow direction setting will temporarily become 1 when the temperature of  
the air flow is low at the start of the Heating mode.  
Horizontal Air Direction Adjustment  
Press the SET button (Horizontal)(Fig. 6 b10).  
G Each time the button is pressed, the air direction range will change as follows:  
1
2
3
The remote control unit’s  
display does not change.  
En-10  
SWING OPERATION  
Begin air conditioner operation before performing this procedure.  
To select SWING Operation  
Press the SWING button (Fig. 6 b11).  
The SWING Display (Fig. 7 c8) will light.  
Each time the SWING button is pressed, the swing operation will change in the  
following order.  
Up/down swing operation  
Left/right swing operation  
Swing operation stops  
Up/down/left/right swing operation  
To stop SWING Operation  
Press the SWING button and select STOP.  
Airflow direction will return to the setting before swing was begun.  
About Swing Operation  
G Up/down swing: Swing operation begins using the  
following range according to the current airflow direc-  
tion.  
G Left/right swing: The airflow-direction louvers move  
(swing) in the left/right airflow direction.  
G Up/down/left/right swing: The airflow-direction louvers  
move (swing) in both the up/down and left/right airflow  
directions.  
G The SWING operation may stop temporarily when the  
air conditioners fan is not operating, or when operating  
at very low speeds.  
Airflow direction is 15 (for cooling, dry).  
With the upper airflow-direction louver in the  
horizontal position, the lower airflow-direction  
louver moves (swings) to direct airflow to a wide  
area.  
Airflow direction is 37 (for heating).  
With the airflow-direction louvers set for down-  
ward or straight down airflow, airflow is directly  
mainly at the floor.  
G If the SET button(Vertical) is pressed during the up/  
down swing operation, the up/down swing operation  
will stop and if the SET button(Horizontal) is pressed  
during the left/right swing operation, the left/right  
swing operation will stop.  
COIL DRY OPERATION  
The Indoor unit can be dried by pressing the COIL DRY button on the Remote Control Unit so as to avoid going moldy and  
restrain the breed of bacterium.  
The COIL DRY Operation will operate for 90 minutes after pressing the COIL DRY button and it will stop automatically.  
To select COIL DRY Operation  
Press the COIL DRY button (Fig. 6 b4) during operation or when  
it stops.  
The COIL DRY Indicator lamp (yellow) will light.(Then OPERATION Indicator lamp  
doesn’t light.)  
The COIL DRY Display (Fig. 7 c4) will light. Then it will disappear after 10 seconds.  
To cancel COIL DRY Operation  
Press the START/STOP button (Fig. 6 b8) during COIL DRY  
Operation.  
When the COIL DRY Display  
Light up: Press the START/STOP button once  
Light off: Press the START/STOP button twice.  
The COIL DRY Indicator lamp (yellow) (Fig.3 a7) will go out.  
Then the operation stops.  
About COIL DRY Operation  
G Press the COIL DRY button again during COIL DRY Operation, COIL DRY Opera-  
tion can be reset.  
G The COIL DRY Operation cannot get rid of the existed mould or bacterium, and it  
has no sterilization effect either.  
En-11  
MINIMUM HEAT OPERATION  
The room temperature can be maintained at 50°F by pressing the MIN. HEAT button  
(Fig.6 b3) so as to prevent the room temperature from falling too far.  
While MINIMUM HEAT OPERATION  
is in progress, the following opera-  
tions/features cannot be used  
TIMER  
To use MINIMUM HEAT OPERATION  
Press the MIN. HEAT button (Fig.6 b3)  
SLEEP  
FAN SPEED  
SWING  
To stop MINIMUM HEAT OPERATION  
Press the START/STOP button (Fig.6 b8)  
Then the operation stops.  
About the MINIMUM HEAT OPERATION  
The Heating mode will not operate if the room temperature is high enough.  
MANUAL AUTO OPERATION  
Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable.  
How To Use the Main Unit Controls  
G When the air conditioner is operated  
with the controls on the Main Unit, it  
will operate under the same mode as  
the AUTO mode selected on the Re-  
mote Control Unit (see page 7).  
Press the MANUAL AUTO button (Fig. 2 a2) on the main unit  
control panel.  
To stop operation, press the MANUAL AUTO button (Fig. 2 a2) once again.  
(Controls are located inside the Open Panel)  
G The fan speed selected will be AUTO”  
and the thermostat setting will be  
standard.(76°F)  
En-12  
CLEANING AND CARE  
G Before cleaning the indoor unit, be sure to turn it off.  
CAUTION!  
G Be sure the Open Panel (Fig. 4 a9) is installed securely.  
G When removing or replacing the air filters, be sure not to touch the heat exchanger, as personal  
injury may result.  
Cleaning the Open Panel  
Cleaning the Air Filter  
1. Remove the Open Panel.  
1. Open the Open Panel, and remove the air  
filter.  
1 Place your fingers at both lower ends of the grille  
panel, and lift forward; if the grille seems to catch  
partway through its movement, continue lifting up-  
ward to remove.  
Lift up the air filters handle, disconnect the two lower  
tabs, and pull out.  
Air filter (Right & Left)  
2 Pull past the intermediate catch and open the Open  
Panel wide so that it become horizontal.  
Open Panel  
Hooks(two places)  
Air filter handle  
2. Remove dust with a vacuum cleaner or by  
washing.  
Mounting  
shaft  
After washing, allow to dry thoroughly in a shaded place.  
3. Replace the Air Filter and close the Open  
Panel.  
1 Align the sides of the air filter with the panel, and push  
in fully, making sure the two lower tabs are returned  
properly to their holes in the panel.  
Knob  
2. Clean with water.  
Remove dust with a vacuum cleaner; wipe the indoor  
unit with warm water, then dry with a clean, soft cloth.  
3. Replace the Open Panel.  
Hooks(two places)  
2 Close the Open Panel.  
1 Pull the knobs all the way.  
(In the above figure, the open panel is omitted for the expla-  
nation.)  
2 Hold the grille horizontal and set the left and right  
mounting shafts into the bearings at the top of the  
panel.  
3 Press the place where the arrow on the diagram indi-  
cates and close the Open Panel.  
G Dust can be cleaned from the air filter either with a vacuum  
cleaner, or by washing the filter in a solution of neutral  
detergent and warm water. If you wash the filter, be sure  
to allow it to dry thoroughly in a shady place before rein-  
stalling.  
G If dust is allowed to accumulate on the air filter, airflow  
will be reduced, lowering operating efficiency and increas-  
ing noise.  
G During periods of normal use, the Air Filters should be  
cleaned every two weeks.  
Mounting  
shaft  
G Don't operate the air conditioner with being opened the  
open panel.  
Bearing  
Knob  
G When used for extended periods, the indoor unit may accumulate dust inside, reducing its performance. We recommend  
that the indoor unit be inspected regularly, in addition to your own cleaning and care. For more information, consult  
authorized service personnel.  
G When cleaning the indoor units body, do not use water hotter than 104 °F, harsh abrasive cleansers, or volatile agents  
like benzene or thinner.  
G Do not expose the indoor units body to liquid insecticides or hairsprays.  
G When shutting down the indoor unit for one month or more, first allow the fan mode to operate continuously for about  
one-half day to allow internal parts to dry thoroughly.  
En-13  
Air Cleaning Filter Installation  
2. Remove the air cleaning filters attached  
to the frames of the front panel.  
1. Open the Open Panel and remove the Air  
filters.  
3. Replace them by two new Air cleaning  
filters.  
2. Attach the air cleaning filter to the frame  
of the front panel.  
1 Remove the old air cleaning filters in reverse order of  
their installation.  
G Attach the filter on the inside of the tabs (6 places) so  
2 Install in the same way as for installation of the air  
cleaning filter set.  
as not to stick out.  
4. Install the two Air filters and close the  
Open Panel.  
Air cleaning filter frame  
G Don't operate the air conditioner with being opened  
the open panel.  
About the Air Cleaning Filters  
Tabs (6 places)  
POLYPHENOL CATECHIN AIR CLEANING FILTER (one sheet)  
G The Air Cleaning Filters are disposable filters. (They can  
not be washed and reused.)  
G For storage of the Air Cleaning Filters, use the filters as  
soon as possible after opening the package.  
(The air cleaning effect decreases when the filters are left  
in the opened package)  
Air filter  
G Generally, the filters should be exchanged about every  
three months.  
Please buy designed air cleaning filters (UTR-FC03-2) (Sold  
separately) to exchange the used dirty air cleaning filter.  
(In the above figure, the open panel is omitted for  
the explanation)  
[Negative air ions deodorizing filter (one sheet) — light blue]  
G The filter should be exchanged about every three years  
so as to maintain the deodorizing effect.  
3. Install the two Air filters and close the  
Open Panel.  
G Filter frame is not a one-off product.  
Please buy designed deodorizing filter (UTR-FC03-3) (Sold  
separately) when exchanging the filter.  
G Don't operate the air conditioner with being opened  
the open panel.  
Maintenance of Deodorizing Filters  
In order to maintain the deodorizing effect, please clean the  
filter in the follow way once three months.  
1 Remove the deodorizing filter.  
G When air cleaning filters are used, the effect will increased  
by setting the fan speed to High.  
2 Clean with water and dry in the air.  
1) Flush the filter with high-pressure hot water until  
the surface of the filter is covered with water. Please  
flush with diluent neutral detergent.  
Never wash by reaming or rubbing, otherwise it  
will damage the deodorizing effect.  
2) Rinse with water flow.  
3) Dry in shade.  
3 Reinstall the deodorizing filter.  
Replacing dirty Air cleaning filters  
Replace filters with the following components (purchased sepa-  
rately).  
POLYPHENOL CATECHIN AIR CLEANING FILTER : UTR-FC03-2  
G
G Negative air ions deodorizing filter: UTR-FC03-3  
1. Open the Open Panel and remove the Air fil-  
ters.  
En-14  
TROUBLESHOOTING  
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-  
WARNING!  
trical breaker or disconnect the power supply plug, and consult authorized service personnel.  
Merely turning off the units power switch will not completely disconnect the unit from the power  
source. Always be sure to turn off the electrical breaker or disconnect the power supply plug to  
ensure that power is completely off.  
Before requesting service, perform the following checks:  
Symptom  
See Page  
Problem  
Doesnt operate immedi-  
ately:  
G If the unit is stopped and then immediately started again, the com-  
pressor will not operate for about 3 minutes, in order to prevent  
fuse blowouts.  
NORMAL  
FUNCTION  
G
Whenever the Power Supply Plug is disconnected and then re-  
connected to a power outlet, the protection circuit will operate for  
about 3 minutes, preventing unit operation during that period.  
G During operation and immediately after stopping the unit, the  
sound of water flowing in the air conditioners piping may be  
heard. Also, noise may be particularly noticeable for about 2 to 3  
minutes after starting operation (sound of coolant flowing).  
G During operation, a slight squeaking sound may be heard. This is  
the result of minute expansion and contraction of the front cover  
due to temperature changes.  
Noise is heard:  
G
During Heating operation, a sizzling sound may be heard occasional.  
This sound is produced by the Automatic Defrosting operation.  
16  
G Some smell may be emitted from the indoor unit. This smell is  
the result of room smells (furniture, tobacco, etc.) which have  
been taken into the air conditioner.  
Smells:  
G During Cooling or Dry operation, a thin mist may be seen emitted  
from the indoor unit. This results from the sudden Cooling of  
room air by the air emitted from the air conditioner, resulting in  
condensation and misting.  
Mist or steam are  
emitted:  
G During Heating operation, the outdoor units fan may stop, and  
steam may be seen rising from the unit. This is due to Automatic  
Defrosting operation.  
16  
Airflow is weak or stops:  
G When Heating operation is started, fan speed is temporarily very  
low, to allow internal parts to warm up.  
G During Heating operation, if the room temperature rises above  
the thermostat setting, the outdoor unit will stop, and the indoor  
unit will operate at very low fan speed. If you wish to warm the  
room further, set the thermostat for a higher setting.  
G During Heating operation, the unit will temporarily stop opera-  
tion (between 7 and 15 minutes) as the Automatic Defrosting mode  
operates. During Automatic Defrosting operation, the DEFROST  
Indicator Lamp (yellow) will flash.  
16  
G The fan may operate at very low speed during Dry operation or  
when the unit is monitoring the rooms temperature.  
6
6
G During SUPER QUIET operation, the fan will operate at very low  
speed.  
G In the monitor AUTO operation, the fan will operate at very low  
speed.  
6
Water is produced from  
the outdoor unit:  
G During Heating operation, water may be produced from the out-  
door unit due to Automatic Defrosting operation.  
16  
En-15  
TROUBLESHOOTING  
Items to check  
Symptom  
See Page  
G Is the Power Supply Plug disconnected its outlet?  
G Has there been a power failure?  
CHECK ONCE Doesnt operate at all:  
MORE  
G Has a fuse blown out, or a circuit breaker been tripped?  
G Is the timer operating?  
8 - 9  
G Is the Air Filter dirty?  
G Air the air conditioners intake grille or outlet port blocked?  
Poor Cooling performance:  
G Did you adjust the room temperature settings (thermostat) cor-  
rectly?  
G Is there a window or door open?  
G In the case of Cooling operation, is a window allowing bright sun-  
light to enter? (Close the curtains.)  
G In the case of Cooling operation, are there heating apparatus and  
computers inside the room, or are there too many people in the  
room?  
G Is the unit set for SUPER QUIET operation?  
6
5
The unit operates  
differently from the Remote  
Control Units setting:  
G Are the Remote Control Units batteries dead?  
G Are the Remote Control Units batteries loaded properly?  
If the problem persists after performing these checks, or if you notice burning smells, or both the ORERATION Indicator Lamp  
(Fig. 3 a4) and the TIMER Indicator Lamp (Fig. 3 a5) flashes, or only the TIMER Indicator Lamp (Fig. 3 a5) flashes, immediately  
stop operation, disconnect the Power Supply, and consult authorized service personnel.  
OPERATING TIPS  
Operation and Performance  
Microcomputer-controlled Automatic Defrosting  
Heating Performance  
G When using the Heating mode under conditions of low  
outdoor temperature and high humidity, frost may form  
on the outdoor unit, resulting in reduced operating per-  
formance.  
In order to prevent this kind of reduced performance, this  
unit is equipped with a Microcomputer-controlled Auto-  
matic Defrosting function. If frost forms, the air condi-  
tioner will temporarily stop, and the defrosting circuit will  
operate briefly (for about 7-15 minutes).  
G This air conditioner operates on the heat-pump princi-  
ple, absorbing heat from outdoor air and transferring that  
heat indoors. As a result, the operating performance is  
reduced as outdoor air temperature drops. If you feel that  
insufficient heating performance is being produced, we  
recommend you use this air conditioner in conjunction  
with another kind of heating appliance.  
G Heat-pump air conditioners heat your entire room by  
recirculating air throughout the room, with the result that  
some time may be required after first starting the air con-  
ditioner until the room is heated.  
During Automatic Defrosting operation, the DEFROST In-  
dicator Lamp (yellow) will light.  
AUTO Restart  
In Event of Power Interruption  
G
If a power failure occurs during TIMER operation, the timer  
will be reset and the unit will begin (or stop) operation at the  
new time setting. In the event that this kind of timer fault  
occurs the TIMER Indicator Lamp will flash (see Page. 4).  
G The air conditioner power has been interrupted by a  
power failure. The air conditioner will then restart auto-  
matically in its previous mode when the power is restored.  
G Operated by setting before the power failure.  
G Use of other electrical appliances (electric shaver, etc.) or  
nearby use of a wireless radio transmitter may cause the  
air conditioner to malfunction. In this event, temporarily  
disconnect the Power Supply Plug, reconnect it, and then  
use the Remote Control Unit to resume operation.  
En-16  
OPERATING TIPS  
Temperature and Humidity Range  
Cooling Mode  
Dry Mode  
Heating Mode  
About 5 to 75 °F  
About 86 °F or less  
Outdoor temperature  
Indoor temperature  
About 14 to 115 °F  
About 64 to 90 °F  
About 14 to 115 °F  
About 64 to 90 °F  
G If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may  
operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of  
lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.  
G Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary  
dwellings.  
G If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor  
unit, and drip onto the floor or other objects underneath. (About 80% or more).  
G If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device,  
the outdoor unit may stop operation for certain period of time.  
SPECIFICATION  
TYPE  
HEAT & COOL MODEL  
MODEL INDOOR UNIT  
OUTDOOR UNIT  
ASU9RLS  
AOU9RLS  
ASU12RLS  
AOU12RLS  
POWER SUPPLY  
COOLING  
208/230 V 60 Hz  
208/230 V 60 Hz  
9000 BTU/h  
0.52 kW  
2.6 A  
12000 BTU/h  
0.83 kW  
3.9 A  
CAPACITY  
INPUT POWER  
CURRENT  
HEATING  
CAPACITY  
12000 BTU/h  
0.80 kW  
3.7 A  
16000 BTU/h  
1.20 kW  
5.5 A  
INPUT POWER  
CURRENT  
En-17  

Briggs Stratton 422499 User Manual
Carrier 50EJ User Manual
Friedrich US14 User Manual
GE ASQ05LL User Manual
GE General Electric Air Conditioner AQV05 User Manual
Graco Ultra Clear PD106594B User Manual
Haier HPRD12HC5 User Manual
Holley Carburetor none User Manual
Honeywell HZ 617C User Manual
HP Hewlett Packard PHOTOSMART C4380 User Manual